Diagnostics
The Cisco Nexus 3550-H Hydra (formerly ExaLINK Hydra) incorporates many in-built diagnostics functions that can be used to monitor the device.
Sensors and monitors
The Nexus 3550-H contains many useful statistics that can be read from the various sensors on the device.
The show environment
command will show temperature sensors, fan speeds and power supply statistics.
admin@EXALINK-HYDRA# show environment
Sensor Temperature
--------------- -----------
1V0_X 35.38 C
1V0_Y 49.88 C
1V0_Z 48.00 C
1V8 41.00 C
CDR 47.98 C
CPU 26.80 C
Crosspoint 33.45 C
FPGA_K7 36.79 C
FPGA_S7 31.00 C
Mainboard_Left 32.62 C
Mainboard_Right 31.00 C
NVME0 44.00 C
PSU1 39.50 C
PSU2 34.00 C
Port_ethernet10 37.14 C
Port_ethernet11 41.44 C
Port_ethernet12 43.00 C
Port_ethernet13 31.23 C
Fan Module Fan 1 RPM Fan 2 RPM Fan 3 RPM Fan 4 RPM Direction
---------- --------- --------- --------- --------- -------------
FAN1 1867 1772 1877 1731 front-to-back
FAN2 1942 1720 1885 1758 front-to-back
FAN3 1769 1737 1739 1738 front-to-back
Power Supply Input Voltage Input Current Input Power Output Voltage Output Current Output Power Fan Direction
------------ ------------- ------------- ----------- -------------- -------------- ------------ -------------
PSU1 238.50 V 0.47 A 60.00 W 12.07 V 4.12 A 50.00 W front-to-back
PSU2 239.50 V 0.36 A 36.00 W 12.08 V 2.25 A 26.00 W front-to-back